Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

Re: LF: Valve LF amps and tank coil size / voltage rating?

To: [email protected]
Subject: Re: LF: Valve LF amps and tank coil size / voltage rating?
From: Andy Talbot <[email protected]>
Date: Sun, 15 Nov 2015 19:29:30 +0000
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=6Z+PyA/mctogpFgMimtQfq/4mgxksrDc1ktZSEeKtTk=; b=HuQrRzQazmPjiYGynqdByzwh6ucYh7HGfjyUKVFYueUgt6eyGrh5BOSYdVKA4nvZBR 8BoU7PiAHwvxcBeqfQxnMlbdufDYVLN/HzD8IMUdXQ4d1K7PFApXgFFCJkt4cH+Pn3cM BhEkY/4Ii8GRctAsL2AKwZuqAJFDA8v0JxRMUFdIL9ViScFSxi+s6mdkihQGRpMeUXlu rTn9Xyj15+pQBNjERpR2/r7+xoNyA51Du0KbpvOE5RBhfuUON2pMBnofooo9D/VuI6s9 5Z77uxYE+737UiV4T0wppGCFM/8gIyCOOEDeUli0yTf28pu5cH8cdq78BXE+Lpq5tuWR 5cBg==
In-reply-to: <59E5AA723F314A4DB597D0C13A05319F@Clemens0811>
References: <[email protected]> <CAA8k23QCEuZ597sXyik94OWPUK42hnvCn2e_pJDeo73c7wGUaA@mail.gmail.com> <[email protected]> <[email protected]> <59E5AA723F314A4DB597D0C13A05319F@Clemens0811>
Reply-to: [email protected]
Sender: [email protected]
AH  HA  .........
I see the significance of your question.   176 = 4 * 44 :-)

That factor 4.44   (or 4,44)   is actually SQRT(2) * PI

'jnt


On 15 November 2015 at 09:18, Clemens Paul <[email protected]> wrote:
 >V = 4.44.F.N.A.B = 176.F.N.A.B ?

Written in "German notation":
4,44 x F x N x A x B

73
Clemens
DL4RAJ

>-----Original Message-----
>From: [email protected]
>[mailto:[email protected]] On Behalf Of DK7FC
>Sent: Saturday, November 14, 2015 11:37 PM
>To: [email protected]
>Subject: Re: LF: Valve LF amps and tank coil size / voltage rating?



<Prev in Thread] Current Thread [Next in Thread>