Dkim-signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=v/MUa0bweV8EQYwhz5xTASjsdWk1gdG7wXtO7Lnmtlw=; b=aeIiVdJ5D89LvVr49BMVfsV7xjPf5oaktVBErL5vzvtXFkfeR4Nd7Y4TWCa7A6ayzF BiNGeI91Q0zCfIDu6xIwenxZ1UHkkHAUqL+JOznr3xxJNFl2YnINjTCElXjfNmvrf42g xT+DyxvXnXoX81fsYkjOM6ChI6YTU4KPo4iEAaM/1BW+5WvA0dLFqbGFmC7RQnzLpTuJ cmTvf5X2iPWxs44ug6quMltpKmwLVDyv7+pivGFCMDfbEEG7U4Chp7ZhVibJNlXQiAj8 2xy++XjiNv20iFajuP9yJsuEgV8GMyXTXZFPMP34odsMU/TlmBTi+w+DXly8ubc+1lN7 +F3A== |
In-reply-to: | <[email protected]> |
References: | <[email protected]> |
Reply-to: | [email protected] |
Sender: | [email protected] |
I'll say it again V = 4.44.F.N.A.B (all SI units)THAT is how you size ferrite cores. It tells you more or less everything you need to know to make ferrite transformers. Keep B to less than 0.1 at these frequencies But.. why would you want to use valves? Expensive, unreliable, high voltages... 'jnt On 14 November 2015 at 19:06, Chris Wilson <[email protected]> wrote: 14 November 2015 |