To All from PA0SE Ian wrote: When making the signal strength measurements using a loop antenna should A resonated loop produces more signal but has to be calibrated by means of a pair of Helmholtz coils. The voltage induced in an aperiodic loop follows from a simple formula, that can be found in Terman. So there is no need for calibration when the loop is used with a selective level meter. 73, Dick, PA0SE |