Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

Re: LF: W-G SPM-19 trouble

To: [email protected]
Subject: Re: LF: W-G SPM-19 trouble
From: "James Moritz" <[email protected]>
Date: Wed, 04 Dec 2002 15:13:49 +0000
In-reply-to: <[email protected]>
References: <[email protected]>
Reply-to: [email protected]
Sender: <[email protected]>
Dear Matti,

At 16:38 04/12/2002 +0200, you wrote:
I have SPM-19 too but without any manuals. Could you plase check what kind
of input  impedance is in "unbal 75" but selected without termination
(infinite).

The manual says " > 10kohm//60pF" in the infinite impedance position.

The additional attenuation caused by connecting this input across a 75 ohm system is specified as less than 0.05dB at frequencies up to 1MHz.

Cheers, Jim Moritz
73 de M0BMU