Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

RE: LF: PA0SE Field Srength Meter for 137 kHz

To: [email protected]
Subject: RE: LF: PA0SE Field Srength Meter for 137 kHz
From: [email protected]
Date: Mon, 24 Nov 2003 16:50:33 +0100
Reply-to: [email protected]
Sender: <[email protected]>
Thread-index: AcOympj+A65IqRCqSKGAqw1T6oyg2QAB2G5Q
Thread-topic: LF: PA0SE Field Srength Meter for 137 kHz
carefully reading should show a difference and the correct expression is  P = 
0.0111(E * d)^2
or is it still wrong for Eudora (the difference is the sign for exponent)

73 LA8AK

-----Original Message-----
From: [email protected]
[mailto:[email protected]]On Behalf Of Eric KD5UWL
Sent: 24. november 2003 15:44
To: LF-Group
Subject: Re: LF: PA0SE Field Srength Meter for 137 kHz


On Mon, 24 Nov 2003, Dick Rollema wrote:

produces a certain field strength is wrongly given as
P = 0.0111(E * d)^2.

The correct formula is:

P = 0.0111(E *d)2 in which:

Hi, Dick,

Sorry -- I don't see the difference.  Did you include the wrong one?

73
Eric





<Prev in Thread] Current Thread [Next in Thread>