Vernall wrote: Once calibrated, the detailed (horizontal roll-out) displays have good (crystal like) frequency accuracy and stability, however the wideband (vertical roll-out) display shows twice the error compared to before calibration was applied. Bob and the list,this is caused by the fact that the full band view (vertical scroll) uses a different sampling rate than the horizontal one. Presently Argo has the provision for calibrating just this latter. I have in the enhancement list for the next version also a double calibration. 73 Alberto I2PHD |