Autocrypt: | addr=[email protected]; prefer-encrypt=mutual; keydata= xsFNBFqj1+0BEACggWlaH8oG/AiXSUG3CeQwZ1NrVEP4U7YsA9N9XEffjCDEsnTjHF2BJSgS 2AicyomkmTGvghEHxrNFfFw07jwgJl97ae/VtNxpERPSE98mb4sPOMpJbwddioMazMDXwhKA wpg5fse+Ru8OrIT04KK919xL/pZuAP6pY6d2kVoizjJOfS71pHpiU6N6q3d9cl+w7d2LKhAE a3A1ZgDquPvn0WQlrN8K5D66xVrwTRhf1b5H4Ozl8/mMJzCeLG1ZIsDB3Pu2flwE81P8dCJA y1azwgY8pTEshVk4em/se9uRiZaDJr/qUSCf6hrV7AGa8g1jpAQDmdGpDNYMqyDqXen4jNi1 8kNFVu1BMl2vjaI8skw/YPxIxlk/0ROHYhN6SuoDq1mt4AW4FryNa7k3A8dM8Bt7udBoTv0i uw4j9R/bmh2vl/QaHRUhDco0xn2z6geWvXkKqha++vzXDrEKUuqgB85SDZPs5W/phs9p0pz1 xA61d1gn8FQJtpou5dQuAucqMo8eKQY5LUcbC+MH5pebH+M2wIuDCBmFPJHQDSPNepeaxJ4o G/HU1hrpzlgLiTTSKR8DcwtMQwYywnCTlm8MgL4jXuPzoGyKDMYyKIjC51G+3AAOJ6oXJAGR g0ehhCPtmnCGBaRlUIoUSpbgc4B+onqFKZmDiVm9CRNJhKIWrQARAQABzRZOMUJVRyA8cGF1 bEBuMWJ1Zy5jb20+wsF9BBMBCAAnBQJao9ftAhsjBQkJZgGABQsJCAcCBhUICQoLAgQWAgMB Ah4BAheAAAoJECRS/J8srRGjPBsQAIh+Haz9gqrQJ0OlMI5xmQ0A5nsVWcatWF/Ea4mucNjL 4n4jmW+Z4Ukn3OVss55chWwrOVMRNWU2d2zRc92ZF7yJhLCoJFV870bZfxNYwdJ3GEBLIu6/ anmQYX0oXFx8UBsx5K6egNqbeflPA7zrLiQkWrz6JApECdiA1rHDjyJdS7PDxBCG9cKgr/5b r4Rn/JlUl9pRPnxlSwHXsV+J6JtFYtWI69MWIVD7Y7OY1wO9+684uOnzeDANzeIwpBDcSm6p 0D5u0b1hfPl2TD0ozVs6P0NvxkMbimXUhRR1QD0FvydyxmZTLAo+XZDGR8GqWYrYrauoRZ1h 3m23+bNT2T4AuoFnWekpsZu+sxIf0LKPtEZCa51O65jZ810ROpXg9Lx71gEoQD+kbjO69+kq 9r7wjytDq/jyhpOGrGYV6kgcQrISY86t9YvkA9Of2HDzZLih3GwecW6fkeV1AO5w4RteE9nL zIs2siGw2YqavF6LpTH71Db7cUYyZWn5hkKpwfpLNnPEuqgZACovpH1WUHx+KMqqIL4rMVCH GcSLqnH2KF4cEDb6OeTbwuLfpGlN+I3j24eQnB2uz5rDa7/IBjsClLl8S/wdDTP8IikBGixX 06v3k06tk/OF4UsfJ0cY/ASGP5+kjT4ASMZAIikwVMpKi5A5be77vecKNYlJQ2a6zsFNBFqj 1+0BEACaujZXo3F17v7QTnub4DjjYvm+nr8J0uU5pPc1UMEz9eWjmtmITm15fx1hPKNtVW+I VlT+DG+ShNnYmO2M4CFBoc7PwkAOc70aDxfHz20kotvj1HhXG7oBiqPkN3TK4C7qWV1HUEPA V960qPdhsoCqmtkvNwj39w1T0ZR5qwwaqDogs9UwBib7zseQ3OXHG32xYYCMcxM35hgXGkkz R7wFL4ZnAPOeFb8LnWtZcrGpwXdsYkXuCxm+A+u9KlFY+w3ZCzZt1F9Ie+/PSZnFIUtbXt2i mfc+VkRwOLz5BDAeWuDL09TN81+gbrR3kXlymDcCbuduO/yHOQK085qzE3LuImdy+JNb7oDf 1C/hvpRvtB02vVy33rzIXT8644SJzFY/mw/W39/BgHKCoL1FrBbfgf0UoIFw5M752i7jQwmv j5yFfnVAXIPpCuusMwWMGVpZcGV7QxJxh0HBEhYgOo9v3zKwzNIPm9V/LA67u/rj4a/MlCE0 mpd6IHaePE1vXDaboPZHZdhAziru5/Jd7KQI0k+HmM/HRANPRNDZ4UeBpgj9PzS6hDN5GHlZ fRUbI8JAg9wSaQtEn0bjyaR7lw0yngZTvvjT1Qqt5zGwm1IAall2STes5xK0aS7p+UJJMVbf ydZ5VOnocvUkwYxbiqoyuVtGxi4tpWW9CRstYXMkAwARAQABwsFlBBgBCAAPBQJao9ftAhsM BQkJZgGAAAoJECRS/J8srRGjTDMP/18q7uhac/naxoFsOqhgXIlvaPgu6GX7s/QOh+bcSV1F y50lxo51P/C95H2TVME/CtCjk2xWQcNjWtXloMEsZpl7T3qWgJHvyZYkDtgh3M6UNY+zb08U K9E2+rR0AZ6zdMKio7Z1xA9BtbUpSZpvy2NgjoYVqo35NllUWMZJq0u+88PvE5WeCIqLipNI EZmUcG9UwolQbPkrRc42ReL+bFbuXGXDA5GbQ0RudXbugI8iUwaw3ftaKElIZtuHW0hw1VrU 9tVHsxKyEoKgNNT1hr+dgRmvCHmA87Pi4R5cMV0ZkLVOYfPX1motedag7HmSNPi2PkYLts4z kyvPEJe2IvaPvjvK1ShRWWgje3uytrhfwyjUZcIuA76RWEfBbwT2Mbrn9O7LvrYtbTiTlsLo Zdk2uocuefBvPd2oI7mTn5eLy/VDy2JVnlb9vpZZhriXI4KtCcP6mYyuPxlxqj/30Kn1fU5b C4EpnKy6hW1CHM42DbwzT+ChjBpFbX9bfwT4qn6d42+T4mN5wkmfnBRHfcn8Wf1ezRSK3Ome Esa3ZDssj23CZHe11uec6Ln14qoB7JyRT9qM3Q99tzvAlmWFM3GrSsG94g4JponQjQWHmr8B eMYezwJHzSI7zWElJpzs/OuohstTYfYTy16FygUOEinc1K4ywjEklgRpXRtjKvqc |
In-reply-to: | <CAA8k23Re61N=nn-jqme8=gXTdX8HUtQ7i0B7n2m1qGqagJdYgQ@mail.gmail.com> |
Openpgp: | preference=signencrypt |
References: | <[email protected]> <CAA8k23Re61N=nn-jqme8=gXTdX8HUtQ7i0B7n2m1qGqagJdYgQ@mail.gmail.com> |
Reply-to: | [email protected] |
Sender: | [email protected] |
User-agent: | Mozilla/5.0 (X11; Linux x86_64; rv:52.0) Gecko/20100101 Thunderbird/52.7.0 |
I am still not sure whether I am using that equation correctly. Chris, if you will forgive me for tagging along on your post, I'm trying to get this equation sorted in my head. Put no faith in anything I say with regard to this! ;-) Andy, could you please check me out on this? Let's use the case Chris asks about as an example. Suppose I want to calculate the maximum RMS voltage to stay out of saturation. The manufacturer of the core states its Ae (equivalent cross sectional area) is 1.58 cm^2. I believe that works out to 0.000158 m^2. F = 137000 I do not know if I should be using 4 turns or 8 turns for the primary. It's 4+4. I will assume 8. Vrms = 4.44 * 137000 * 8 * 0.000158 * 0.1 Vrms = ~77V Does that look right? As for practical application I have no idea what this means. The equation uses Vrms but we're talking about something closer to a square wave than sine wave. But then it's not really a square wave either... Paul On 05/03/2018 10:00 AM, Andy Talbot wrote: > By measuring the voltage across the winding using a scope, then > seeing what Bmax is using teh equation > > Vrms = 4.44.F.N.A.B > > F Hz N turns A core cross-sectional area in metres^2 B tesla > > If B works out higher than about 0.1 for a ferrite core, then you > are approaching saturation > > Andy > www.g4jnt.com <http://www.g4jnt.com> > > > On 3 May 2018 at 14:46, Chris Wilson <[email protected] > <mailto:[email protected]>> wrote: > > > > Hello LF'ers > > In say a W1VD power amp, or in general, how can you test if the > output transformer is > starting to saturate please? Thanks. > > http://www.w1vd.com/137-500-KWTX.html > <http://www.w1vd.com/137-500-KWTX.html> > > > > -- > Best regards, > Chris mailto:[email protected] > <mailto:[email protected]> |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: LF: How can you tell if a Class D amp output transformer is starting to saturate?, Andy Talbot |
---|---|
Next by Date: | Re: LF: How can you tell if a Class D amp output transformer is starting to saturate?, Andy Talbot |
Previous by Thread: | Re: LF: How can you tell if a Class D amp output transformer is starting to saturate?, Andy Talbot |
Next by Thread: | Re: LF: How can you tell if a Class D amp output transformer is starting to saturate?, Andy Talbot |
Indexes: | [Date] [Thread] [Top] [All Lists] |