| Dkim-signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:in-reply-to:references:from:date:message-id:subject:to; bh=LdAsl7rjVeYzg+vLmAiy+7e3TSduN7O5vB5W/UJCLMA=; b=VbzZ6VAUiOEQDAWwBiPnBiGB/9R/IMg5GUdE11jgYCcEh91QI9TzoaUx0SaVxyeAvr BfbStn9aDgQZHvzZvdE4qfj/hTfPUKgsDDOnfhFnb1jNqi4gq1Ieeok2CBjVhyxX9szk 8MYHCK0Vyw1Nr5AAQYmGPIZIgsRxrGor54YyhdTdSgei2rSC2i8clIWbLK2rZRdjQQ7N d31KhwiLHkllFpxqoiZr2SVCJMRla8hRcaoozeArd19xE1iYreoD1su5DK/52dGE1ao8 Mw0y/7rdknnYV4t6AKRNlmG0HxRJp9wabJPq0XaeXyMBEjchfP9EU6LCeXHb6qu73J17 8x8g== |
| In-reply-to: | <[email protected]> |
| References: | <[email protected]> |
| Reply-to: | [email protected] |
| Sender: | [email protected] |
|
By measuring the voltage across the winding using a scope, then seeing what Bmax is using teh equation Vrms = 4.44.F.N.A.B F Hz N turns A core cross-sectional area in metres^2 B tesla If B works out higher than about 0.1 for a ferrite core, then you are approaching saturation Andy On 3 May 2018 at 14:46, Chris Wilson <[email protected]> wrote:
|
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | LF: How can you tell if a Class D amp output transformer is starting to saturate?, Chris Wilson |
|---|---|
| Next by Date: | Re: LF: How can you tell if a Class D amp output transformer is starting to saturate?, N1BUG |
| Previous by Thread: | LF: How can you tell if a Class D amp output transformer is starting to saturate?, Chris Wilson |
| Next by Thread: | Re: LF: How can you tell if a Class D amp output transformer is starting to saturate?, N1BUG |
| Indexes: | [Date] [Thread] [Top] [All Lists] |