Dkim-signature: v=1; a=rsa-sha256; q=dns/txt; c=relaxed/relaxed; d=abelian.org ; s=default; h=Content-Transfer-Encoding:Content-Type:In-Reply-To: MIME-Version:Date:Message-ID:From:References:To:Subject:Sender:Reply-To:Cc: Content-ID:Content-Description:Resent-Date:Resent-From:Resent-Sender: Resent-To:Resent-Cc:Resent-Message-ID:List-Id:List-Help:List-Unsubscribe: List-Subscribe:List-Post:List-Owner:List-Archive; bh=Sl7EiAzmufL5MKonRP7/w4UAMNa4X99Bd7xlQsBsX2o=; b=B/mkMchmrKZjFJxReCZvgSsj4L Ss4SHjcJBwAKFedC67ZTS4lbLgGpfhVrmFDOA6V94LXjxR3rDP2/5F3u+v0MejaUMIr61/SHFE+iw +SOep7xSiTgcYhTtkJhycZ3wDrGcnQSYcm1Cx4s+eOEaxg2chAE1yXey1oLDBWwljhGo=;
In-reply-to: <[email protected]>
References: <[email protected]> <[email protected]>
Reply-to: [email protected]
Sender: [email protected]
User-agent: Mozilla/5.0 (X11; Linux x86_64; rv:52.0) Gecko/20100101 Thunderbird/52.3.0

Jim wrote:

> Considerably reducing DC-DC converter output filter
> capacitance and/or load current can almost always solve
> the problem of erratic power supply startup related to
> high source resistance,

When I checked the data sheet for the IP1215S isolating
DC-DC converter I spotted that it said max 47uF load
capacitance - and I had 100uF hanging on each rail.

Hopefully that's the answer.  For some reason I can't
reproduce the start-up problem in the office even though
I've got slightly higher cable resistance.

I like these XP power IP series converters, good isolation
and they have a large input voltage range.

--
Paul Nicholson
--