| Dkim-signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=RKpmROK3uyDBHQyZ1ba2pUiLn8mkJPyafQSCSCBdEw0=; b=ZwQsE+LKWtSRijvzJPJmyITbfQqu4fcmyl2fBcUo/V4xNDn5o8LyaOZb3pkL2gix/T FTjqzQFS0ImilLqDt+skzXpzSkEGKCK15YpaldPeDnNx7xQjb/W49C2HkjqNNlwaMtzy RpGA96XOAGKiuikrlo1aWNW5h/Casbin4GVqfUj6clMr1Dlqv25iDKOAWld2clbTS/EI Y1EKDd47yfRNO0Tk5LY9+G0xxf/zcroT/1JMSb3qiUQbGojApmMADZpi6+AxPld+hoj0 oqcCT+6/WamqDT7QO1gsHiDcDAmcQ2ExHXWvPVcp7pLC5mIpiy5rGuyVs8T78hyeioRs NJdQ== |
| In-reply-to: | <[email protected]> |
| References: | <CAMFjj70DNUWTSecPCaRhvr8aZFXtE8Z_xSDxVyOE609iNTS+RQ@mail.gmail.com> <7E7DFBB4D102A04DB5ADC88D66628A4A0FB5C6C9@ICTS-S-MBX5.luna.kuleuven.be> <[email protected]> |
| Reply-to: | [email protected] |
| Sender: | [email protected] |
Hi Marco,
Thanks for the note about PLC. I suspect that the utilities here
are using some very old equipment and are reluctant to change it. This
is a shame since many times there have been reports about the
vulnerability of the power grid (mostly concerning hacking), yet there
is a resistance to change. Very odd.
73 Warren K2ORS
On Tue, Dec 4, 2012 at 4:03 AM, Marco IK1ODO -2 <[email protected]> wrote:
> And there is nothing about PLC, only the secondary service statement.
>
> Marco IK1ODO / AI4YF
>
>
>
> At 09:04 04-12-12, Rik Strobbe wrote:
>
>> in most European countries the access to the 2200m band is based on
>> CEPT/ERC Recommendation 62-01 E that states that "the band 135.7-137.8 kHz
>> may be used with a maximum e.r.p. of 1 Watt on a secondary basis by the
>> Amateur Service in CEPT countries"
>>
>> So it's 1W ERP instead of 1W EIRP, a 2.15dB difference (in favour of ERP).
>>
>> For most stations however this limit is not an issue as due to practical
>> restrictions they don't run more than some 10 or 100mW.
>>
>>
>>
>> 73, Rik ON7YD - OR7T
>
>
>
--
73 Warren K2ORS
WD2XGJ
WD2XSH/23
WE2XEB/2
WE2XGR/1
|
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: LF: RE: 137kHz Rules and Regs, Warren Ziegler |
|---|---|
| Next by Date: | Re: LF: RE: 137kHz Rules and Regs, Marco IK1ODO -2 |
| Previous by Thread: | Re: LF: RE: 137kHz Rules and Regs, Marco IK1ODO -2 |
| Next by Thread: | Re: LF: RE: 137kHz Rules and Regs, Marco IK1ODO -2 |
| Indexes: | [Date] [Thread] [Top] [All Lists] |