Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

Re: LF: Advisory / Warning

To: [email protected]
Subject: Re: LF: Advisory / Warning
From: Roger Lapthorn <[email protected]>
Date: Thu, 27 Jan 2011 15:30:21 +0000
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=gamma; h=domainkey-signature:mime-version:in-reply-to:references:date :message-id:subject:from:to:content-type; bh=92dywl/ojxeVhhHXwa1tVKSKe6MMsJ/2IQQlzPZ5SWc=; b=efRjte0tVdn+ZFNpVNgOccTqzjb8IMeAtbM0nctkX1MPopaQv3q153CMMvb5KUZh9/ g4sjz3AFfVY/6lL0OsTflfflAMWG+xYO6yX0zwWr49BmhpEg4Tx1hbs8UNUb1ZRGlioE MAan87RrRHgUQbaPQh6F6J5PdpV3n+mSTk8As=
Domainkey-signature: a=rsa-sha1; c=nofws; d=gmail.com; s=gamma; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; b=XMmkAUicNrST5CxwLUR6XsQzmzo9Z2A9pJ/qqf2sOMp1rQGEaK10WqN2B3YPZ+wSWv c5B5vFxkBboeZdpVo9LZ/BvPQnoW204XlZLjfSoj3QPZvlpp3DIs82gbQFD1oI0E1M5w eeWLpZSDvjRsOYzIitbER3BOZnbigpx0pAfFA=
Domainkey-status: good (testing)
In-reply-to: <[email protected]>
References: <[email protected]>
Reply-to: [email protected]
Sender: [email protected]
Another good reason to sticking to QRP I say!

73s
Roger G3XBM

On 27 January 2011 15:06, Andy Talbot <[email protected]> wrote:
Thought I'd better warn QRO LF ops about this - something that had never occured to me before, and could be nasty.
 
I'm laying floor panels in my loft space, and this involves rerouting some of the upstairs lighting wiring - drilling holes and feeding the wire though rather than it laying on top of joists where the flooring will sit.  Anyway, there I was, was happily threading twin-and-earth cable by torchlight (*) when I suddenly got a nasty RF burn holding one end of a piece
 
The 500kHz WSPR beacon is running, and the bit I was holding was isolated from the house main earth wire.  The Tee antena runs outside over the roof, only 3m or so away from where I was working.   So more than enough pickup with me and a bit of wire forming a dipole in the near field of 4kV at 500kHz
 
Now, bearing in mind the burnt ATU cabin of a few months ago, it made me think...
Large bits of bare isolated wire or metal in roof spaces where LF antennas pass over could be risky.   They could pick up enough voltage to spark - and if there's paper/ wood / plastic at the sparking point, an RF spark that always seems to turn into an arc, is very hot.
 
Just a thought.
 
(*) and BTW, there is a very strong argument for not having your roofspace light on the same circuit as your normal upstaris lighting
 
Andy
 



--
g3xbm-qrp.blogspot.com/
www.g3xbm.co.uk
www.youtube.com/user/g3xbm
G3XBM   GQRP 1678    ISWL G11088