Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

Re: LF: Re: E-Field Probe calibration question

To: [email protected]
Subject: Re: LF: Re: E-Field Probe calibration question
From: "Johan H. Bodin" <[email protected]>
Date: Thu, 01 Apr 2010 17:00:11 +0200
In-reply-to: <[email protected]>
References: <[email protected]> <001d01cad190$aa92e590$0901a8c0@lark> <[email protected]>
Reply-to: [email protected]
Sender: [email protected]
User-agent: Mozilla/5.0 (Windows; U; Windows NT 5.1; sv-SE; rv:1.9.1.9) Gecko/20100317 Thunderbird/3.0.4
Andy Talbot wrote:
> Now, what was the voltage from an untuned loop, again ;-?

V = 2*Pi*f*N*A*u0*H = 2*Pi*f*N*A*B

Where
f [Hz]
N [turns]
A [m^2]
H [A/m]
B [Tesla]
u0 = 4*Pi*10^-7

If not properly aligned with the field, multiply by cos(angle).

http://vk1od.net/antenna/SmallUntunedSquareLoop/
http://sidstation.lionelloudet.homedns.org/antenna-theory-en.xhtml

73
Johan SM6LKM


<Prev in Thread] Current Thread [Next in Thread>