Oops..

I forgot H = E/Zspace = E/(120*Pi) (plane wave in the far field)

where
H is mag. field strength [A/m]
E is elec. field strength [V/m]

/Johan

Johan H. Bodin wrote:
> Andy Talbot wrote:
>> Now, what was the voltage from an untuned loop, again ;-?
> 
> V = 2*Pi*f*N*A*u0*H = 2*Pi*f*N*A*B
> 
> Where
> f [Hz]
> N [turns]
> A [m^2]
> H [A/m]
> B [Tesla]
> u0 = 4*Pi*10^-7
> 
> If not properly aligned with the field, multiply by cos(angle).
> 
> http://vk1od.net/antenna/SmallUntunedSquareLoop/
> http://sidstation.lionelloudet.homedns.org/antenna-theory-en.xhtml
> 
> 73
> Johan SM6LKM
> 
> 