Copied with constant reference phase carrier phase: 73.9 carrier Eb/N0: 10.2 dB carrier S/N: 23.83 dB in 31.2 uHz, -21.22 dB in 1Hz, -55.20 dB in 2.5kHz Regarding CRCs, I think now I must recommend
Am 06.05.2017 18:17, schrieb Paul Nicholson: These seem to be typical, where the decode goes astray for several characters, then comes back. It seems to involve runs of about 3 to 5 constraint length
Hi Stefan. I know this fail! I suggest a thermostat on the heat sink that remove the MOSFET DC supply. http://uk.rs-online.com/web/p/thermostats/2282636/ 73 de Claudio ik2pii -- ZE-Light e ZE-Pro: s
Hello Claudio, Thanks for the suggestion. I know these thermostats. There is one in the power supply that i used for VLF some months ago. The thermostat failed, the fan stopped, the supply became so
Congratulations! Jim AA5BW Decoded after a bit of work "THIS IS A NEW LONGEST EBNAUT MESSAGE ON VLF. 881 KM ON THE 36 KM BAND. JOIN THE VLF ACTIVITIES! 73!" list rank: 0 constant reference phase carr