Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:references:in-reply-to:from:date:message-id:subject:to; bh=llteKOn4pRjxzAFGipdmrv3fM5fd3jlkeU9EGnEOfIA=; b=QiW+zggkRzphfrXVZ3HnVraAHYgtxQ0L3ql+4O+ixnkbOvnKli+FD4q+fYz6Oc5CBY PHJbkn/xX0ZpZVTXyr8HDTTia0w9jnk08EvQNPfh1XvfHqpulpdm4whLb8U1G1QWNleF JlCGVbyTmFns3sPwjZL8bJ9CbXf3pQIkIZG7GklnNOaWnOyrFQzRQpPVU65vnGy06yoC 9SoFEWiqRTdjed7QAfNF8aUkMZHZ6OmVmg5u6yR36EGW6m5KQt1OK9CYCFExkLVRh6sT S6lJk4MkgNky9v1o+Hg3khFurWbCukOyzfxksN1OHR4dp+VB3n/PEP2oQXC6kpqdoMBw wCyg==
In-reply-to: <[email protected]>
References: <[email protected]> <[email protected]>
Reply-to: [email protected]
Sender: [email protected]

Hi Markus,

thank you for the colour phase meter implemeted on your RDF instance, very useful for me last night. It was reproducing exactly the phase displayed on my SL's spectrogram, even in case of interruption, unless slight variations due to propagation.

All the best

73 de Riccardo IW4DXW


Il giorno Ven 25 Gen 2019, 00:59 Markus Vester <[email protected]> ha scritto:
Hi Ric,

Good idea! You can check the effect on my grabber: I've injected an auxiliary carrier into the right channel of the topmost speclab instance, so the colour on your frequency indicates phase instead of azimuth. If you like you could temporarily interrupt the carrier and verify that it comes back with same phase.

Autodecoders are looking out for you and Joe, like last night.

Best 73,
Markus

 


-----Ursprüngliche Mitteilung-----
Von: Riccardo Zoli <[email protected]>
An: LF Group <[email protected]>
Verschickt: Do, 24. Jan. 2019 23:56
Betreff: LF: NEO-M8T and H-mixer (SDR)


LF,

I'm testing a useful trick to allow a quadrature generator to mantain a stable and nominal phase using a GPS module NEO/LEA-M8T.
Normally, an IC 74HC74 is used to generate the quadrature LO signals for a H-mixer (typically in a SDR "Softrock style").
Clocking the IC with TP2 signal (f * 4, so 544 kHz to obtain a 136 kHz frequency conversion), there is a 90 deg. step phase ambiguity. Furthermore, with an undesiderate glitch on the reference clock signal, the phase could wrongly rotate.
So: resetting (clear) the two D flip-flops of the 74HC74 on rising edge of the 1PPS pulse, already reference for PC audio-card, we can keep nominal phasing which is restored every second.


All the best


73 de Riccardo IW4DXW