| To: | [email protected] |
|---|---|
| Subject: | Re: LF: 137 from /p |
| From: | wolf_dl4yhf <[email protected]> |
| Date: | Thu, 04 Aug 2011 18:00:00 +0200 |
| In-reply-to: | <[email protected]> |
| References: | <[email protected]> |
| Reply-to: | [email protected] |
| Sender: | [email protected] |
| User-agent: | Mozilla/5.0 (Windows NT 5.1; rv:5.0) Gecko/20110624 Thunderbird/5.0 |
Hi Stefan, You asked: > BTW, Wolf/YHF, is there an input for a CW key on the RS232? <Not directly. But there are functions to poll some signal on the serial port, see http://www.qsl.net/dl4yhf/speclab/interpr.htm#ptt_port_cmds and there are commands to turn the signal generator on / off: http://www.qsl.net/dl4yhf/speclab/sign_gen.htm#generator_cmdsYou could use the 'conditional actions', which are updated every few hundred milliseconds, to connect a serial port bit to the generator. Not good enough for conventional CW, only for relatively slow keying. 73, Wolf DL4YHF . |
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: LF: QSY, Daniele Tincani |
|---|---|
| Next by Date: | LF: conds...beacon, Stefan Schäfer |
| Previous by Thread: | LF: 137 from /p, Stefan Schäfer |
| Next by Thread: | Re: LF: 137 from /p, Stefan Schäfer |
| Indexes: | [Date] [Thread] [Top] [All Lists] |