John,

I am using a 1A thermo-couple meter and 1/2 ratio current transformer (to get a 4A range) since 2 years on 500kHz, without any problem. At 500kHz the values it shows are give or take 10%, so it is OK for tuning the antenna / controlling antenna current but I wouldn't rely on it for measuring the exact current.

73, Rik  ON7YD - OR7T

At 06:41 19/01/2010, you wrote:
Hello....

Can the typical thermo-couple amp meter be placed in the antenna
lead-in.  I have had several fail open after a few days use.  They were
not close to any metallic grounded objects, or subject to over current.
No lightning

73  John / VE7BDQ   (VX9BDQ)