1. VLF: A single turn RX loop for VLF (score: 1)
Author: DK7FC <[email protected]>
Date: Wed, 27 Apr 2016 18:31:20 +0200
Hi VLF, Today i've installed a second loop into the tree. It is a simple copper tube having 10 mm diameter and about 4m length. https://dl.dropboxusercontent.com/u/19882028/VLF/20160427_084708.jpg Th
/rsgb_lf_group-archives/html/rsgb_lf_group/2016-04/msg00338.html (14,632 bytes)

2. Re: VLF: A single turn RX loop for VLF (score: 1)
Author: Wolfgang Büscher <[email protected]>
Date: Wed, 27 Apr 2016 19:11:55 +0200
Hello all, I can confirm such a single-turn loop with a big ferrite transformer works well - even with a very simple amplifier. Construction details and a few spectrograms at : http://www.qsl.net/dl4
/rsgb_lf_group-archives/html/rsgb_lf_group/2016-04/msg00340.html (15,650 bytes)

3. Re: VLF: A single turn RX loop for VLF (score: 1)
Author: Lubos <[email protected]>
Date: Wed, 27 Apr 2016 17:30:39 +0000
Hello Stefan and Wolf! I used to try single-loop antenna some years ago. It worked well. 73! Lubos, OK2BVG Hello all, I can confirm such a single-turn loop with a big ferrite transformer works well -
/rsgb_lf_group-archives/html/rsgb_lf_group/2016-04/msg00342.html (17,067 bytes)

4. Re: VLF: A single turn RX loop for VLF (score: 1)
Author: Paul Nicholson <[email protected]>
Date: Wed, 27 Apr 2016 17:52:39 +0000
You can eliminate the transformer by having more turns in the loop. But you'll probably find when you do the arithmetic, that it is cheaper to have fewer turns (or one turn) and a transformer. Also f
/rsgb_lf_group-archives/html/rsgb_lf_group/2016-04/msg00344.html (13,378 bytes)

5. Re: VLF: A single turn RX loop for VLF (score: 1)
Author: DK7FC <[email protected]>
Date: Wed, 27 Apr 2016 20:51:31 +0200
Hello Paul, Am 27.04.2016 19:52, schrieb Paul Nicholson: You may also find a lower thermal noise floor with few turns and a transformer, compared with the same loop area and many turns. Yes and i can