Hi Larry,For most thermocouple ammeters, 60 Hz is sufficient to check calibration. The discrepancy between 60 Hz and 137 kHz should not exceed a very few percent. If your AC source is substantially sinusoidal, a fairly common DVM with at least a 3 amp scale will do the job quite nicely. 73, John |