Return to KLUBNL.PL main page

Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*LF\:\s+Re\:\s+Current\s+mode\s+class\s+D\s+PA\s+for\s+475\s+kHz\s+\-\s+success\s*$/: 3 ]

Total 3 documents matching your query.

1. Re: LF: Re: Current mode class D PA for 475 kHz - success (score: 1)
Author: <[email protected]>
Date: Thu, 31 May 2012 14:27:24 -0400
Stefan Well ... guess you have already answered your own question ;~) I've stuck with transformer coupled designs ... VMCD for 137 / 500 kHz and CMCD for 160 / 75 / 40 meters. I don't have much exper
/rsgb_lf_group-archives/html/rsgb_lf_group/2012-05/msg00028.html (14,881 bytes)

2. Re: LF: Re: Current mode class D PA for 475 kHz - success (score: 1)
Author: Stefan Schäfer <[email protected]>
Date: Thu, 31 May 2012 18:37:02 +0200
Jay, MF, I just tried the CMCD and immediately achieved 89% efficiency at 12VDC and 36W RF at 475 kHz (dummy load). Just a first result. I can answer my own question now: Without a load the PA behave
/rsgb_lf_group-archives/html/rsgb_lf_group/2012-05/msg00473.html (11,911 bytes)

3. Re: LF: Re: Current mode class D PA for 475 kHz - success (score: 1)
Author: Stefan Schäfer <[email protected]>
Date: Fri, 01 Jun 2012 00:53:58 +0200
Hi Jay, LF, Thanks very much again! Well, if the PA efficiency is 90% with standard parts, what can you achieve with the speial core material? I can obtain the 77 ferrite material here but never hear
/rsgb_lf_group-archives/html/rsgb_lf_group/2012-06/msg00215.html (15,724 bytes)


This search system is powered by Namazu