1. LF: Re: Arcing relays &c. (score: 1)
Author: "James Moritz" <[email protected]>
Date: Wed, 12 Oct 2011 09:59:21 +0100
Dear Joe, LF Group, Feeding this into 3 mH (X=2500 ohm at 137.8 kHz) gives 11.2 kV (17 kV peak) so relays in series as suggested by G8FZK and G3NYK should work well. It is a bit more complicated than
/rsgb_lf_group-archives/html/rsgb_lf_group/2011-10/msg00141.html (15,881 bytes)

2. Re: LF: Re: Arcing relays &c. (score: 1)
Author: Stefan Schäfer <[email protected]>
Date: Wed, 12 Oct 2011 12:50:58 +0200
Joe, As i was i child i played with some 10 kV transformers which are used as ignition transformers in oil ovens. Also some HV TV cascade experiments were done. To discharge the loaded C's i took a m
/rsgb_lf_group-archives/html/rsgb_lf_group/2011-10/msg00404.html (15,777 bytes)

3. Re: LF: Re: Arcing relays &c. (score: 1)
Author: "Graham" <[email protected]>
Date: Wed, 12 Oct 2011 13:02:13 +0100
Jim Yes , that's a limiting factor, The Delco open frame relays have quite a considerable, 'coil to contact' distance and some 4 / 5 mm contact gap, 2 or 3 mounted in line, daisy chained would produc