Return to KLUBNL.PL main page

Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*LF\:\s+G4HUP\s+aerial\s+current\s+meter\/\s+hazards\s*$/: 4 ]

Total 4 documents matching your query.

1. LF: G4HUP aerial current meter/ hazards (score: 1)
Author: "Dr. Wolf Ostwald" <[email protected]>
Date: Sat, 5 Aug 2017 07:38:38 +0200
good morning ! a current transformer with ferrites of unknown origin and virtues is a very risky thing. As these cores are widely available on swapmeets its a lure to use them. But they can be tested
/rsgb_lf_group-archives/html/rsgb_lf_group/2017-08/msg00014.html (11,325 bytes)

2. Re: LF: G4HUP aerial current meter/ hazards (score: 1)
Author: Wolfgang Büscher <[email protected]>
Date: Sat, 5 Aug 2017 08:53:00 +0200
... and never forget to wind a 'secondary' over the current transformer, always terminated with low resistance. Otherwise you will quickly saturate it, which is something that NO current transformer
/rsgb_lf_group-archives/html/rsgb_lf_group/2017-08/msg00016.html (12,332 bytes)

3. Re: LF: G4HUP aerial current meter/ hazards (score: 1)
Author: Andy Talbot <[email protected]>
Date: Sat, 5 Aug 2017 08:08:33 +0100
Leaving the secondary of a current transformer open-circuit  once caused half a city to be blacked out when the 400kV grid network tripped http://www.g4jnt.com/Hams_Hall_Investigation_Report.pdf Quit
/rsgb_lf_group-archives/html/rsgb_lf_group/2017-08/msg00017.html (13,922 bytes)

4. Re: LF: G4HUP aerial current meter/ hazards (score: 1)
Author: DK7FC <[email protected]>
Date: Sat, 05 Aug 2017 10:47:59 +0200
Moin, A current transformer without a secondary winding is no current transformer but a simple coil. And most likely a bad one. Current transformer is by definition a transformer that has nearly a sh
/rsgb_lf_group-archives/html/rsgb_lf_group/2017-08/msg00019.html (13,042 bytes)


This search system is powered by Namazu