Hi Lf's in all circuit
diagrams I find filters like
12nF---->54uH---->27nF----->54uH----->12nF here is the 3db
point at 250khz. Has anyone test a filter in this configuration
47nF-----> 54uH----->82nF------54uH----->47nF here is the 3db
point at 147khz. The 2. filter gives a better suppress of the
harmonics! Wat is the reason that all use the fist one?
best 73' Tom
DL4EAU
Lower insertion loss.
At 1200 Watts every 0.1dB counts. and with a push pull design,
the second harmonic should be very low.....it's the odd order harmonics you need
to worry about.
Regards
David
|
|