To: | [email protected] |
---|---|
Subject: | Re: LF: Re: Ringing Voltage on Telephone, boo-boo |
From: | [email protected] |
Date: | Thu, 8 Nov 2001 01:50:49 EST |
Reply-to: | [email protected] |
Sender: | <[email protected]> |
I don't know how it is in Canada, but in the States, the 20Hz component is
the only ringing voltage sent across the line to the telephone set, which can
readily be confirmed by sticking a blocking capacitor and a bridging
transformer acorss the line and looking at the result directly on an
oscilloscope. The modulated audio frequency tones are sent from the
switching office back to the caller, not to the recipient.
Locally, the ringing voltage is 90V RMS, riding on the normal on-hook DC of about 50 volts. 73, John |