Hi Mal,
the Philips data sheet says:

3C85 SPECIFICATIONS

SYMBOL    CONDITIONS                 VALUE        UNIT
ui      25 °C; <10 kHz; 0.1 mT      2000 ±20%
ua     100 °C; 25 kHz; 200 mT       5500 ±25%
B        25°C; 10 kHz; 250 A/m       >400          mT
100 °C; 10 kHz; 250 A/m >330 Pv 100 °C; 25 kHz; 200 mT <140 kW/m^3
      100 °C; 100 kHz; 100 mT       <165
rho     DC; 25 °C                  approx. 2      ohm m
Tc                                   >200          °C
density                         approx. 4800      kg/m^3


Note that the (initial) permeability goes from 1700 to 4000 in the range from 0°C to 100°C...


73 de

                               IN3OTD, Claudio

Hi All
Does anyone know the permability and spec of 3c85 material? I cannot find
this info in any of my tech info books.
The T200 series seem very low like u10 powdered iron whereas the 3c5 ferrite
type are as high as u7000
Seems important to get the right mix
g3kev