20 LOG (V1/V2)= 20dB down
About 10 Watts - but still a lot.

We all fall into that dB trap from time to time I bet !!!!!!!

Andy


An interesting number:

If Jim's measurement of MM0ALM's field strength is right, at 50 uV/m, and assuming the distance between them is 600 kms mainly over a standard medium-conductivity land path then :
According to the CCIR standard propagation curves (Vol 5, "Propagation in 
non-ionised media", Recommendation 368-4)  a radiated power of 1 kW at 136 
kHz  from a short vertically-polarised monopole would produce a field 
strength at Jim's distance  of 500 uV/m.
Jim measured 50 uV/m so MM0ALM's radiated power must be 10 dB below 1 kW - 
100 watts.  Jim's measurements I have found to be pretty accurate in the 
past but if anyone else can make accurate field strength measurements 
perhaps they would do so next time MM0ALM comes on.



--