Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

Re: LF: RE: VLF - vertical probe measurements

To: [email protected]
Subject: Re: LF: RE: VLF - vertical probe measurements
From: Chris Osborn <[email protected]>
Date: Fri, 15 Apr 2011 14:22:12 +0100 (BST)
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoo.co.uk; s=s1024; t=1302873733; bh=+EUrrwssjxgEO/i4WMpOhaLxdnLlp230hZzZX/kJhuc=; h=Message-ID:X-YMail-OSG:Received:X-Mailer:Date:From:Subject:To:In-Reply-To:MIME-Version:Content-Type; b=HJRQzHpWR9dx4dcne8ow0B5jcQ8MWyIJLmrUi7Es0/tAgob7GXiYb/FDkueE1Aa58cIP5ehtK9zKQ3pRp1F0wB+AmXY4m2xIz4fmRqliTZ+i0pP1j33rZYscRFGjbetgJhNmDt8ed3hkKOj1ebzSzHb2FUa27X7fElbiEgh3jng=
Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=s1024; d=yahoo.co.uk; h=Message-ID:X-YMail-OSG:Received:X-Mailer:Date:From:Subject:To:In-Reply-To:MIME-Version:Content-Type; b=F4EgsOa1hYrVtjRI0r9H/H08r+6WkAEhPAURE1sq9wvR0ce5KvazHa1DMx4HqCdUh9vM4KewYb93t4YJXgQ1HnWHsiF9zAN2dmMgQfOd8q2BnwGKFLpjLrtFRV1n6pQ87SGZQzl8hd8UVA4H7t+Hv6Y+23M6qkeSAiKIq3lQhw4=;
Domainkey-status: good (testing)
In-reply-to: <BF4A524700075746A6467658DFC7102C88B4A7886C@ICTS-S-EXC2-CA.luna.kuleuven.be>
Reply-to: [email protected]
Sender: [email protected]
Hello Stefan / Rik,
 
Thanks for the response.
 
I adjust the PA current by varying the drive level to the FET's so the PA supply voltage stays constant.
I should have made that clear.
 
73 Chris G3XIZ

--- On Fri, 15/4/11, Rik Strobbe <[email protected]> wrote:

From: Rik Strobbe <[email protected]>
Subject: LF: RE: VLF - vertical probe measurements
To: "[email protected]" <[email protected]>
Date: Friday, 15 April, 2011, 14:11

Hello Chris,
 
maybe a stupid question (wouldn't be my first one): how do you alter the PA current ?
If you change the PA current by changing the PA voltage then the output power will change more or less with the square of tht PA current (P = UxI and you change both U and I), what would result in a linear behaviour between PA current and probe voltage.
 
73, Rik  ON7YD - OR7T
 

Van: [email protected] [[email protected]] namens Chris Osborn [[email protected]]
Verzonden: vrijdag 15 april 2011 14:40
Aan: LF Group
Onderwerp: LF: VLF - vertical probe measurements

LF,
 
Acting on advice I have installed a whip aerial (probe) on top of a mast at the boundary of my property.
This is in order to monitor my VLF transmissions and to provide a reference level for any system improvements.
 
I noticed that the probe's pick-up voltage is directly proportional to my PA's supply current.
Assuming that the PA efficiency doesn't change drastically with current then would I be correct in assuming that the probe's voltage is directly proportional to the radiated power?
 
I was expecting a square law relationship . .
 
73
Chris G3XIZ
<Prev in Thread] Current Thread [Next in Thread>