Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

Re: R: LF: Re: I: Fw: For today the FETs survived...

To: [email protected]
Subject: Re: R: LF: Re: I: Fw: For today the FETs survived...
From: Chris Wilson <[email protected]>
Date: Fri, 2 Jun 2017 14:14:18 +0100
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=from:date:message-id:to:subject:in-reply-to:references:mime-version :content-transfer-encoding; bh=LwWKLWV+FKy8VGVINRyn/W4L9iNRJI5RggYEnCR1I8I=; b=Oi/kdGXwtC/gkwqQZubDpgAraYdZw0QM1P1U+/Jd2Kz8asKgbO/Qb5uXjZ0ak4xpwM 8MXJDbTUOGOUTBbyvp57XN9e2XGkONcvEsw6HLoYSBOY0yENyCmb0CKDzj7FIW5s8+l5 PQEBSm6rwmvg2fHY4vzJwJWZyUzoEXJHHw9hOjSRcgFc0XHQs1MzqiijZuqFUlFfF8LO RvFXqNqS8trGKHZzPIzHCWZ87YNbrbf1lxczEhXCmh3Y+AawEBgDoAm1ZZuiBF0OXa/2 mUxeUN/LnrFS6KIOMcw7QOQrqzvgV4S9DFpzqab7pF0VF7qXOKiwch+dBdzr6ZmtoiJt IJMQ==
In-reply-to: <[email protected]>
References: <[email protected]>
Reply-to: [email protected]
Sender: [email protected]
Hello Marco,

My  loading coil drifts as it warms up, but that's only when a kW or so
is  run,  not  at  low power. But I think you are testing into a dummy
load?   I  also had a poor drain waveform on one side of my push pull
Class  "D",  that  was  only cured by changing one of the 2 FET's (that
tested  fine  out  of circuit). We "microwavers" are old school now that
people are moving to DC toggled every hour or so ;)



Friday, June 2, 2017, 2:00:07 PM, you wrote:

> Hi Alan,

> and thanks for joining :-)
> it's hard to believe at this stage that is correct to speak of "high 
> currents"..
> The PA is an half bridge like 
> Andy's 700W but now I'm testing at low voltage: I see these problem 
> trepassing the 30Vdc supply level (and power is about 15W)..
> Anyway will try with the "pulse rated caps" you suggested just in case
> my "low current" "low tension" ideas are wrong.
> 73 Marco
















-- 
Best regards,
 Chris                            mailto:[email protected]


<Prev in Thread] Current Thread [Next in Thread>