The experiment was stopped at 12:25 UTC.
The loading coil holds the high voltage. Now i will order another 2 kg
of 0.4mm wire to add more turns...
73, Stefan
Am 07.08.2016 12:20, schrieb DK7FC:
Hi VLF,
Since 10:08 UTC i'm running a test transmission on 5330 Hz. About 240
mA antenna current leads to 12 kV across the D.U.T., my new loading
coil which is intended for 2970 Hz. So far the inductance seems to be
1.9 H.
I want to check if it actually holds the high voltage as to my
estimation before i continue to add more turns. The estimation is that
each winding stack has to hold 5 kV. I will then end up somewhere
between 30 and 40 kV at 2970 Hz...
An image:
https://dl.dropboxusercontent.com/u/19882028/VLF/20160807_114115.jpg
If someone wants to check if the signal is detectable in some
distance....
The signal will be on the air for at least one hour.
73, Stefan
|