To: | [email protected] |
---|---|
Subject: | Re: LF: Selection of spot frequencies for DX |
From: | "James Moritz" <[email protected]> |
Date: | Wed, 26 Mar 2003 11:25:59 +0000 |
In-reply-to: | <001401c2f30a$c5cc0560$269437d2@xtr743187> |
References: | <[email protected]> <[email protected]> <[email protected]> <003201c2f247$ee408200$0100007f@xtr743187> |
Reply-to: | [email protected] |
Sender: | <[email protected]> |
At 07:29 26/03/2003 +1200, you wrote: Hi all,I made a numerical mistake in my last posting. 25 Hz shift at 136 kHz is a ratio of about 0.009, or 0.9%. Of course, we would like the "QRM deviation" of 50 Hz lines to be much less than plus or minus 25 Hz.73, Bob ZL2CA Dear Bob, LF Group,25/136000 = 0.00018, or 0.018% for 25Hz shift - a 0.9% shift in the 50Hz mains frequency would lead to the 2720th harmonic shifting by 1224Hz... Cheers, Jim Moritz 73 de M0BMU |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: LF: Re: T/A tests tonight on 137.7747, Tom Boucher |
---|---|
Next by Date: | LF: TA 26 March, John Andrews |
Previous by Thread: | Re: LF: Selection of spot frequencies for DX, Vernall |
Next by Thread: | Re: LF: Selection of spot frequencies for DX, Vernall |
Indexes: | [Date] [Thread] [Top] [All Lists] |