Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

LF: RF Current meter

To: rsgb_lf_group@blacksheep.org
Subject: LF: RF Current meter
From: "Alberto di Bene" <dibene@usa.net>
Date: Fri, 20 Feb 2004 23:29:14 +0000
In-reply-to: <HNEGLMNKFOEMMNHIFAPIAEOACDAA.g4wgt@talkgas.net>
References: <HNEGLMNKFOEMMNHIFAPIAEOACDAA.g4wgt@talkgas.net>
Reply-to: rsgb_lf_group@blacksheep.org
Sender: <owner-rsgb_lf_group@blacksheep.org>
User-agent: Mozilla/5.0 (Windows; U; Win98; en-US; rv:1.4) Gecko/20030624 Netscape/7.1 (ax)
Wouldn't that mean that you measured the current in a point where the impedance was about 2250 ohm ? (Supposing the 100W were RF power, if the PA efficiency is
less than 100% that impedance is lower).

5 W into 50 ohm -> 0.316 A -> full scale 0.316/0.75 = 0.422 A
50% of that current = 0.211 A
R = W/I^2  = 100/0.211^2 = 2250 ohm

73  Alberto  I2PHD
-------------------------------

G4WGT - Gary wrote:

An interesting occurrence when testing the simple RF clip on current meter
on the bench, I used my Marathon 5w Tx to provide RF to test the meter,
separated a small section of the coax inner & shield, fed into 50R dummy
load & got 75% fsd, so I shunted the meter until it just moved off the
bottom of the scale, went to the base of the LF vertical whilst transmitting
with about 100w DC i/p but there was no reading on the meter, I then removed
the shunt & did the same test & got about a 50% fsd reading, I can't work
that one out.





<Prev in Thread] Current Thread [Next in Thread>