Hello, Dick Rollema wrote: In the Dutch Magazine "Radio-Nieuws"of 1 April 1925 I found a treatment of the multiple tuned antenna by Ir. (later Prof.) Huijdts. It confirms what Rik, ON7YD, expected: In a multiple tuned antenna with N radiators each one has a loading coil of N times the selfinductance of the coil for a singleradiator. Simulation with ELNEC confirms this in general: Not exactly N times higher but somewhat higher, increasing with N. If mistuned at one leg only this leg will degenerate to a loop antenna (via earth, side fed) and the whole system will be a fine dummy or cloud burner at best. 54°16'N / 10°04'E, JO54ag 73 es gl de Peter, DF3LP |