Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

LF: My first ferrite experiments

To: "[email protected]" <[email protected]>
Subject: LF: My first ferrite experiments
From: Daniele Tincani <[email protected]>
Date: Tue, 27 Sep 2011 11:31:55 +0100 (BST)
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=yahoo.com; s=s1024; t=1317119516; bh=oi7X3y3nEm67QqNjuLUgBEkEy7Bq59KeCbWprmOomh0=; h=X-YMail-OSG:Received:X-Mailer:References:Message-ID:Date:From:Reply-To:Subject:To:In-Reply-To:MIME-Version:Content-Type; b=3JnEzryYOthyBXwtw9cdJ0eYOSrpURoz2LPNpqTPCcg92COb8DIpNDUUZl2xsUlibeQP6cT5KljfWYgBxutomGhhG99tmBJPTHeVoUPz49f8MAYPjCUU/cPXSL60IIO6FdLJa4si58/XCFJvF51AkkCkUyNJvtvPEETLmX5X1Lg=
Domainkey-signature: a=rsa-sha1; q=dns; c=nofws; s=s1024; d=yahoo.com; h=X-YMail-OSG:Received:X-Mailer:References:Message-ID:Date:From:Reply-To:Subject:To:In-Reply-To:MIME-Version:Content-Type; b=XxMKISFV/h/lcLhSXpj20e2bQz/TKCGz0sUu7mifVqNFQ7/jhuiSP6ZjFiCg49LaTY8bnm7tWnZCfHUnZOtiC1qFhPHn8x47wSKQjJ5P8ngD8SHGi2CgJIDG/1RjPU56PLEop+o4SDFeAKmgvI4mG0HWEp6UfgeDHFypEh2n9yc=;
Domainkey-status: good (testing)
In-reply-to: <[email protected]>
References: <16BC8B3CA8672445BC2A29B4C14A26D4379ED2AAB4@exlnmb01.eur.nsroot.net> <[email protected]> <[email protected]> <9CD1E11E8BC9402CB4AECECAC4088443@JimPC> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]> <[email protected]>
Reply-to: [email protected]
Sender: [email protected]
 
Hello LF,
 
this evening I had some free time to spend for starting my very simple tests with ferrite rods. Picture 1 in the attached zip file shows one of the rods (about 10mm diameter x 200mm long) together with a short piece of plastic tube that I have used to adapt the rods to a larger-diameter slotted aluminium tube - shown in picture 2. As you can see, the longitudinal cut on the tube is not really regular and "clean". I'm not very good at working with metals. Nevertheless, I hope it will do the job, that is acting as a shield between the rods and the coil. Picture 3 shows two of the three rods I used, each inserted in a short piece of plastic pipe and protected with heat shrink tube and some masking tape.
Finally, picture 4 shows the very provisional setup that I used to try measuring Q of an LC pair composed by a 2-gangs variable capacitor plus a 55-turns coil wound over the aluminium tube containing the ferrite rods. I performed several measures, with 1, 2 or 3 rods inside the tube. I saw that using 3 rods increases the inductance significantly. For example, at an intermediate position of the varcap, resonance was at 1037KHz with only 1 rod inside the tube, but it was at 767 KHz with 3 rods.The Q value also increases slightly using 3 rods, even thought in my tests I got only a miserable figure of about 30. Anyway, I  decided to go with 3 rods for my next step, that will be to try Litz wire for the coil and see what happens.
 
Note: pics 3 and 4 will be attached to a re-sent of this message.
 
Regards
D.