Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

RE: LF: Rogowski-coils for RF measurements

To: <[email protected]>
Subject: RE: LF: Rogowski-coils for RF measurements
From: "Hideho YAMAMURA" <[email protected]>
Date: Tue, 23 Oct 2018 10:42:25 +0900
Dkim-filter: OpenDKIM Filter v2.10.3 conuserg-09.nifty.com w9N1gSeM008523
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=nifty.com; s=dec2015msa; t=1540258948; bh=F9Da77HNBAzWfy++qV31hkTBhCVqUYtEDLzRqGqN1fQ=; h=From:To:References:In-Reply-To:Subject:Date:From; b=BlKhTnkKlNtpcFr6s94L6kfaoQa3wmbGpW13X9cpUOvYQEHoJiVIgGfPyTK/p/4Bs u/S+F17HCxZ+ypDKxFpt+7Br0jNxlmq2Mt6AuNPWGi2FgO5iwldTJcs3iY0uJShJrr OY2v3SLbPI7tFnTOhDbIUtExSrxn9psXOB05goRvcAkhFEpUN8gGZ/DrnpdgMV+YQE nbNy4bMQ3tPoJVdhOeo/pAdumw91PmMG5YZ4r/fvF/o3UNHW726em6yTi/wb1VrCow v8/B2KMpNL1JB8+zNtVWgZ7IfDtIwUUSZ1f6VxXTx+WLxMeJl7zdeU4f8sGTfMya0Q YLdtHF/udYz/w==
In-reply-to: <[email protected]>
References: <[email protected]> <[email protected]> <[email protected]>
Reply-to: [email protected]
Sender: [email protected]
Thread-index: AQGwRLTAa61d8lKR3n3ukFcgT3PCRQMI8f+lAyVi6NalQt1H4A==

Stephan and all,

 

You might be interested in the following, although not Rogowski type,

a cut toroidal core, clamp-type, current transformer + rectifier.

You need a high-impedance voltmeter. A normal handy one will do.

You obtain absolute values, accuracy +-20% (or better).

 

I developed the HF version in circa 2002, and the LF version in 2011.

Distributed as kit and finished version, sold about 4000.

 

Fun to observe RF currents on coax-shield, rotator-cable, AC-cables,

VHF coax while transmitting at HF, LF...,

Probably too small to measure towers: inner-diameter is about 22mm.

 

websites in Japanese, sorry, but see the pictures.

 

HF:

https://www.ddd-daishin.co.jp/e-kousaku/d-rf-current/ver2/index.htm

1.8-54MHz, 10mA-300mA, (accuracy +-20%)

10:1  (1000mV is 100mA)

 

LF:

https://www.ddd-daishin.co.jp/e-kousaku/d-rf-current/ver2/lf/lf-part-set.htm

135kHz-4MHz, 0.05-2A, (accuracy +-20% )

1:1  (1V is 1A)

 

Hideho YAMAMURA, Ph.D, JF1DMQ

 

 

From: [email protected] [mailto:[email protected]] On Behalf Of F6CWN
Sent: Tuesday, October 23, 2018 12:01 AM
To: [email protected]
Subject: Re: LF: Rogowski-coils for RF measurements

 


Hello Stephane!


Maybe this could help you:

http://www.uqac.ca/dsa/archives/projets/2010/conception/rapportFinal/RapFinal_2010-193.pdf

(Limited to ~300 KHz)

73: Jeff F6CWN

 

Le 22/10/2018 à 13:04, DK7FC a écrit :

Hi all,

Has someone ever build (homemade, not bought!) a Rogowski-coil for RF current measurements?
https://en.wikipedia.org/wiki/Rogowski_coil

It could be used to measure leakage currents in a tower near the antenna wire for example. Or for measuring RF currents into a pole of a guide rail, for example :-)

I'm planning to build one and i thought i use 0.4 mm diameter enameled cu wire arround a graden hose, having 0.6m circumference. Then some shrinking tube will be applied. That's the plan.

The circuit looks easy, it should be run from a 9V battery and a simple TL081 for example. The output could be adapted to a multimeter, so there is a digital read-out.

I'm curious to see how it works...


73, Stefan