Return to KLUBNL.PL main page

rsgb_lf_group
[Top] [All Lists]

LF: RE: Soil Conductivity Measurement

To: [email protected]
Subject: LF: RE: Soil Conductivity Measurement
From: "Mike Underhill" <[email protected]>
Date: Mon, 1 Aug 2005 12:03:18 +0100
Delivery-date: Mon, 01 Aug 2005 12:03:58 +0100
Envelope-to: [email protected]
Importance: Normal
In-reply-to: <003301c5967e$422fc600$0600a8c0@router>
Reply-to: [email protected]
Sender: [email protected]

Uwe, I would be very interested in a plot of how the conductivity has varied over the year and in what the largest variation of maximum to minimum that you have found? 

 

It would also be useful to measure at a frequency closer to 136Khz for comparison purposes?  It would have to be at a frequency away from interference and the test signal would have to be strong enough to overcome interference. 

 

Has anyone on the list experience in measuring ground conductivity at such frequencies?

 

Mike – G3LHZ

 

I´am mesuring ground conductivity over almost 1 year regularly

 

today it was 15,6 Ohm / m ( measured with 16Volt@ 50Hz )

 

 

I try to built a measuring device with other frequency , somthing odd ( no multibles from 50Hz, thinking about  111 Hz - )

and automatic daily measurements ( at present times done manually)

 

Would like to discuss about it

 

Uwe, DK1KQ

 

 


--
No virus found in this incoming message.
Checked by AVG Anti-Virus.
Version: 7.0.338 / Virus Database: 267.9.7/60 - Release Date: 28/07/2005


--
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.0.338 / Virus Database: 267.9.7/60 - Release Date: 28/07/2005

<Prev in Thread] Current Thread [Next in Thread>