Marcus, I don't know how much better Litz can do in your case but the winding length is also important for efficiency. If I remember correctly, best efficiency (power transfer) is achieved when the winding covers the entire length of the ferrite rod i.e. the coil uses as much length as possible of the concentrated field . Unfortunately, this does not coincide with maximum coil Q. 73 Johan SM6LKM |