To: | "RSGB LF group" <[email protected]> |
---|---|
Subject: | SV: LF: Field strength revised |
From: | "C Andersson" <[email protected]> |
Date: | Mon, 28 Feb 2000 19:29:48 +0100 |
Reply-to: | [email protected] |
Sender: | <[email protected]> |
ON7YD wrote: If you calibrate the loop it is not nessecary to use an untuned loop. If you use a tuned loop the output voltage will be much higher (factor Q, can easily be 100 or more). This will allow to measure at larger distances. I think there is a point in using an untuned loop (or at least one with low Q). It should be less affected by nearby objects than a high-Q loop. /Christer sm6pxj |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: LF: Field strength revised, Väinö Lehtoranta |
---|---|
Next by Date: | SV: LF: Field strength revised, C Andersson |
Previous by Thread: | Re: LF: Field strength revised, Väinö Lehtoranta |
Next by Thread: | SV: LF: Field strength revised, C Andersson |
Indexes: | [Date] [Thread] [Top] [All Lists] |