Dick's post, made with Eudora, contained this HTML fragment: The correct formula is:<br><br> P = 0.0111(E *d)</font><font size=1><sup>2</sup></font><font size=3> in which ... Depending on your mail
To All from PA0SE A description of my Field Strength Meter for 136 kHz can be found on several web sites. I just found out that on some web sites the formula for the power that produces a certain fie
Ahhh .. excellent. Sorry -- I don't use html email clients for these reflectors and missed the distinction. I did, however, read the )2 as ) ** 2 or )^2 which is what was intended. I just didn't see
produces a certain field strength is wrongly given as P = 0.0111(E * d)2. The correct formula is: P = 0.0111(E *d)2 in which: Hi, Dick, Sorry -- I don't see the difference. Did you include the wrong
carefully reading should show a difference and the correct expression is P = 0.0111(E * d)^2 or is it still wrong for Eudora (the difference is the sign for exponent) 73 LA8AK produces a certain fiel
Hi Eric and all, Dick's post, made with Eudora, contained this HTML fragment: The correct formula is:<br><br> P = 0.0111(E *d)</font><font size=1><sup>2</sup></font><font size=3> in which ... Dependi