Delivered-To: daveyxm@virginmedia.com Received: by 10.50.237.98 with SMTP id vb2cs281698igc; Sun, 9 Feb 2014 13:22:49 -0800 (PST) X-Received: by 10.180.19.35 with SMTP id b3mr7975958wie.20.1391980968044; Sun, 09 Feb 2014 13:22:48 -0800 (PST) Return-Path: Received: from post.thorcom.com (post.thorcom.com. [195.171.43.25]) by mx.google.com with ESMTP id cl9si5643912wib.5.2014.02.09.13.22.47 for ; Sun, 09 Feb 2014 13:22:48 -0800 (PST) Received-SPF: neutral (google.com: 195.171.43.25 is neither permitted nor denied by best guess record for domain of owner-rsgb_lf_group@blacksheep.org) client-ip=195.171.43.25; Authentication-Results: mx.google.com; spf=neutral (google.com: 195.171.43.25 is neither permitted nor denied by best guess record for domain of owner-rsgb_lf_group@blacksheep.org) smtp.mail=owner-rsgb_lf_group@blacksheep.org; dkim=pass header.i=@mx.aol.com Received: from majordom by post.thorcom.com with local (Exim 4.14) id 1WCbO4-0000s8-L2 for rs_out_1@blacksheep.org; Sun, 09 Feb 2014 20:54:00 +0000 Received: from [195.171.43.32] (helo=relay1.thorcom.net) by post.thorcom.com with esmtp (Exim 4.14) id 1WCbO4-0000rz-3X for rsgb_lf_group@blacksheep.org; Sun, 09 Feb 2014 20:54:00 +0000 Received: from omr-m09.mx.aol.com ([64.12.143.82]) by relay1.thorcom.net with esmtps (TLSv1:AES256-SHA:256) (Exim 4.77) (envelope-from ) id 1WCbO1-0004px-BG for rsgb_lf_group@blacksheep.org; Sun, 09 Feb 2014 20:53:59 +0000 Received: from mtaout-mbe01.mx.aol.com (mtaout-mbe01.mx.aol.com [172.26.254.173]) by omr-m09.mx.aol.com (Outbound Mail Relay) with ESMTP id 8FED670000084 for ; Sun, 9 Feb 2014 15:53:54 -0500 (EST) Received: from White (95-91-237-152-dynip.superkabel.de [95.91.237.152]) by mtaout-mbe01.mx.aol.com (MUA/Third Party Client Interface) with ESMTPA id A5D03380000AB for ; Sun, 9 Feb 2014 15:53:49 -0500 (EST) Message-ID: <631F8F343EAC4E8DA718FD19BBACF107@White> From: "Markus Vester" To: References: <002a01cf25d6$de725e60$9b571b20$@com> Date: Sun, 9 Feb 2014 21:53:47 +0100 MIME-Version: 1.0 X-Priority: 3 X-MSMail-Priority: Normal Importance: Normal X-Mailer: Microsoft Windows Live Mail 12.0.1606 X-MimeOLE: Produced By Microsoft MimeOLE V12.0.1606 x-aol-global-disposition: G DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=mx.aol.com; s=20121107; t=1391979234; bh=WsUCfyxRpDYWXWDszmMyxx3Iw//r9/UHhVvGZARiEyk=; h=From:To:Subject:Message-ID:Date:MIME-Version:Content-Type; b=ujvKc3UxI9U1xx95sb3qTsyhcctc4njzCiZOWPbve6Jom6DUipj29hMBTGuHliuuR R2/ijtjDzAjE9dCG4EizE5OnKbUHEqu15vT966zjomiCAoiPP9hCU1UYKWRoC4WOVW yPJvbkniwMu/fhnQi058gHE8basFQWI57BZoUF6w= x-aol-sid: 3039ac1afead52f7eadd6df0 X-AOL-IP: 95.91.237.152 X-Spam-Score: -0.6 (/) X-Spam-Report: Spam detection software, running on the system "relay1.thorcom.net", has identified this incoming email as possible spam. The original message has been attached to this so you can view it (if it isn't spam) or label similar future email. If you have any questions, see the administrator of that system for details. Content preview: Terry, good point: If you retune your RX from 72.7 to 72.8, the FFT center frequency in SpecLab needs to be 100 Hz lower, ie. changed from 1622 to 1522 Hz. Opds.ini entries can stay the same. Best 73, Markus [...] Content analysis details: (-0.6 points, 5.0 required) pts rule name description ---- ---------------------- -------------------------------------------------- -0.0 RCVD_IN_DNSWL_NONE RBL: Sender listed at http://www.dnswl.org/, no trust [64.12.143.82 listed in list.dnswl.org] 0.0 FREEMAIL_FROM Sender email is commonly abused enduser mail provider (markusvester[at]aol.com) -0.0 SPF_PASS SPF: sender matches SPF record -0.6 RP_MATCHES_RCVD Envelope sender domain matches handover relay domain 0.0 HTML_MESSAGE BODY: HTML included in message 0.0 T_DKIM_INVALID DKIM-Signature header exists but is not valid X-Scan-Signature: 50abd45de4f0c3e2f43f634f1225d940 Subject: Re: LF: RE: 74.322 kHz Op-64 from Bob and Dex Content-Type: multipart/alternative; boundary="----=_NextPart_000_0006_01CF25E1.69419A10" X-Spam-Checker-Version: SpamAssassin 2.63 (2004-01-11) on post.thorcom.com X-Spam-Level: X-Spam-Status: No, hits=0.2 required=5.0 tests=HTML_60_70,HTML_MESSAGE, MISSING_OUTLOOK_NAME autolearn=no version=2.63 X-SA-Exim-Scanned: Yes Sender: owner-rsgb_lf_group@blacksheep.org Precedence: bulk Reply-To: rsgb_lf_group@blacksheep.org X-Listname: rsgb_lf_group X-SA-Exim-Rcpt-To: rs_out_1@blacksheep.org X-SA-Exim-Scanned: No; SAEximRunCond expanded to false Dies ist eine mehrteilige Nachricht im MIME-Format. ------=_NextPart_000_0006_01CF25E1.69419A10 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Terry, good point: If you retune your RX from 72.7 to 72.8, the FFT center = frequency in SpecLab needs to be 100 Hz lower, ie. changed from 1622 to = 1522 Hz. Opds.ini entries can stay the same. Best 73, Markus From: Terry GW0EZY=20 Sent: Sunday, February 09, 2014 9:38 PM To: rsgb_lf_group@blacksheep.org=20 Subject: LF: RE: 74.322 kHz Op-64 from Bob and Dex Markus =20 Thanks for opds settings.=20 =20 Sorry - I have to ask for explanation "Opera software users should tune = to 72.8 kHz dial"=20 =20 Should opds users also set 72.8 dial? If not, then can't run Opera and = opds in parallel from same Rx. =20 If so, do I also change the additional SL settings (that worked FB last = night for OP 16): CF=3D1622 RF Offset 72.7 to 72.8 =20 73 Terry =20 From: owner-rsgb_lf_group@blacksheep.org = [mailto:owner-rsgb_lf_group@blacksheep.org] On Behalf Of Markus Vester Sent: 09 February 2014 19:46 To: rsgb_lf_group@blacksheep.org Subject: LF: 74.322 kHz Op-64 from Bob and Dex =20 Bob and Dex intend to transmit Opera-64 tonight, WG4XRS on 74.3213 and = WG5XRS on 74.3229 kHz. =20 Opera software users should tune to 72.8 kHz dial to bring the signals = inside the prescribed Op-64 passband. =20 Opds users can start out from Op-16 settings, but reduce FFT bin size by = a factor of four from 0.954 mHz to 0.238 mHz. =20 Example settings for SpecLab with opds-64: Audio samplerate 12 kHz,=20 FFT decimation divisor 768,=20 FFT length 65536,=20 scroll interval: 20 minutes, number of exported bins: 32768,=20 untick use INTEGER numbers only. =20 Example parameters for opds.ini: opspeed=3D64 spotdelay=3D58 ' seconds fc=3D74322 ' center frequency (Hz) sr=3D12000.86 'enter your calibrated samplerate (Hz) dec=3D50331648 '768*64k=20 =20 73 and good luck, Markus (DF6NM) =20 ------=_NextPart_000_0006_01CF25E1.69419A10 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
Terry,
 
good point: If you retune your RX from = 72.7 to=20 72.8, the FFT center frequency in SpecLab needs to be 100 Hz lower, ie. = changed=20 from 1622 to 1522 Hz. Opds.ini entries can stay the = same.
 
Best 73,
Markus
 

Sent: Sunday, February 09, 2014 9:38 PM
To: rsgb_lf_group@blacksheep.org= =20
Subject: LF: RE: 74.322 kHz Op-64 from Bob and = Dex

Markus

 

Thanks=20 for opds settings.

 

Sorry=20 =96 I have to ask for explanation =93Opera = software users=20 should tune to 72.8=20 kHz dial=94

 

Should=20 opds users also set 72.8 dial? If not, then can=92t run Opera and opds = in parallel=20 from same Rx.

 

If=20 so, do I also change the additional SL settings (that worked FB last = night for=20 OP 16):

CF=3D1622

RF=20 Offset 72.7  to 72.8

 

73=20 Terry

 

From:=20 owner-rsgb_lf_group@blacksheep.org = [mailto:owner-rsgb_lf_group@blacksheep.org]=20 On Behalf Of Markus Vester
Sent: 09 February 2014=20 19:46
To: rsgb_lf_group@blacksheep.org
Subject: LF: = 74.322=20 kHz Op-64 from Bob and Dex

 

Bob and Dex = intend to=20 transmit Opera-64 tonight, WG4XRS on 74.3213 and WG5XRS on 74.3229=20 kHz.

 

Opera = software users=20 should tune to 72.8=20 kHz dial to bring the signals inside the prescribed = Op-64=20 passband.

 

Opds users=20 can start out from Op-16 settings, but reduce FFT bin size by = a factor=20 of four from 0.954 mHz to 0.238 mHz.

 

Example = settings for=20 SpecLab with opds-64:

 Audio = samplerate 12 kHz, 

 FFT=20 decimation divisor 768,

 FFT = length=20 65536,

 scroll=20 interval: 20 minutes,

 number of=20 exported bins: 32768,

 untick use=20 INTEGER numbers only.

 

Example = parameters=20 for opds.ini:

 opspeed=3D64
 spotdelay=3D58=20 ' seconds
 fc=3D74322 ' center frequency = (Hz)
 sr=3D12000.86 =20 'enter your calibrated samplerate = (Hz)
 dec=3D50331648  =20 '768*64k

 

73 and good = luck,

Markus=20 (DF6NM)

 