Return-Path: Received: from post.thorcom.com (post.thorcom.com [195.171.43.25]) by klubnl.pl (8.14.4/8.14.4/Debian-8+deb8u2) with ESMTP id v9UMgXcD011397 for ; Mon, 30 Oct 2017 23:42:35 +0100 Received: from majordom by post.thorcom.com with local (Exim 4.14) id 1e9Igk-0002qH-A5 for rs_out_1@blacksheep.org; Mon, 30 Oct 2017 22:37:46 +0000 Received: from [195.171.43.32] (helo=relay1.thorcom.net) by post.thorcom.com with esmtp (Exim 4.14) id 1e9Igj-0002q8-F7 for rsgb_lf_group@blacksheep.org; Mon, 30 Oct 2017 22:37:45 +0000 Received: from mout02.posteo.de ([185.67.36.66]) by relay1.thorcom.net with esmtps (TLSv1.2:ECDHE-RSA-AES256-GCM-SHA384:256) (Exim 4.89) (envelope-from ) id 1e9Igg-0004Gl-Kc for rsgb_lf_group@blacksheep.org; Mon, 30 Oct 2017 22:37:44 +0000 Received: from submission (posteo.de [89.146.220.130]) by mout02.posteo.de (Postfix) with ESMTPS id 5D30C209A0 for ; Mon, 30 Oct 2017 23:37:40 +0100 (CET) Received: from customer (localhost [127.0.0.1]) by submission (posteo.de) with ESMTPSA id 3yQq9v3Q30z10H4 for ; Mon, 30 Oct 2017 23:37:39 +0100 (CET) Message-ID: <59F7A9B2.90401@posteo.de> Date: Mon, 30 Oct 2017 23:37:38 +0100 From: DK7FC User-Agent: Mozilla/5.0 (Windows; U; Windows NT 6.1; de; rv:1.9.1.8) Gecko/20100227 Thunderbird/3.0.3 MIME-Version: 1.0 To: rsgb_lf_group@blacksheep.org References: <15f5559fe36-c0b-25e91@webjas-vac031.srv.aolmail.net> <59F1F06C.6070805@posteo.de> <59F21BE0.4050509@posteo.de> In-Reply-To: <59F21BE0.4050509@posteo.de> X-Spam-Score: 0.0 (/) X-Spam-Report: Spam detection software, running on the system "relay1.thorcom.net", has NOT identified this incoming email as spam. The original message has been attached to this so you can view it or label similar future email. If you have any questions, see the administrator of that system for details. Content preview: The 10 char message was transmitted beginning on the 27th and 28th. On the 29th and today, the 30th, there was no transmission. The safety function triggered again. Yesterday as i remotely checked what happend, i saw just 70 mA instead of 300 mA. So i expected there is a fault on the coil and it was arcing. [...] Content analysis details: (0.0 points, 5.0 required) pts rule name description ---- ---------------------- -------------------------------------------------- -0.0 RP_MATCHES_RCVD Envelope sender domain matches handover relay domain 0.0 HTML_MESSAGE BODY: HTML included in message X-Scan-Signature: b707651713bcd4ad9db4bb0f5d794041 Subject: Re: VLF: 300 mA on 5170 Hz Content-Type: multipart/alternative; boundary="------------010903080704080205090008" X-Spam-Checker-Version: SpamAssassin 2.63 (2004-01-11) on post.thorcom.com X-Spam-Level: X-Spam-Status: No, hits=0.5 required=5.0 tests=HTML_MESSAGE,HTML_TITLE_EMPTY autolearn=no version=2.63 X-SA-Exim-Scanned: Yes Sender: owner-rsgb_lf_group@blacksheep.org Precedence: bulk Reply-To: rsgb_lf_group@blacksheep.org X-Listname: rsgb_lf_group X-SA-Exim-Rcpt-To: rs_out_1@blacksheep.org X-SA-Exim-Scanned: No; SAEximRunCond expanded to false This is a multi-part message in MIME format. --------------010903080704080205090008 Content-Type: text/plain; charset=UTF-8; format=flowed Content-Transfer-Encoding: 7bit The 10 char message was transmitted beginning on the 27th and 28th. On the 29th and today, the 30th, there was no transmission. The safety function triggered again. Yesterday as i remotely checked what happend, i saw just 70 mA instead of 300 mA. So i expected there is a fault on the coil and it was arcing. Today i carefully inspected each of the 5 buckets and saw some small traces of partial discharges. Added loads of Kapton foil near the critical regions. Then i put the coil together again, but still 70 mA on the SpecLab antenna current plot. But the analog amperemeter near the PA showed > 320 mA! QUickly it became clear that the E field pickup probe near the antenna has dropped down during the strong storm last saturday! This also explains the sporadic interruptions during the 3 carrier experiment. Now the probe is fixed again, the construction should be much more stable. The antenna current is recalibrated. The theoretical phase change should not be significant. A test carrier is now running on 5170.005 Hz for an hour or so. The 100 char message will be transmitted tomorrow 18 UTC for the 3rd time. 73, Stefan Am 26.10.2017 19:31, schrieb DK7FC: > OK, fine. So let's start: > > *f = 5170.1000 Hz > Start time: 26.October.2017 18:00:00 UTC (daily) > Symbol period: 8 s > Characters: 100 > CRC bits: 16 > Coding 8K21A > Duration: 11:18:24h > Antenna current: 300 mA* > > 73, Stefan > > > > Am 26.10.2017 17:38, schrieb Paul Nicholson: >> >> > What abbut your new E field RX, is is ready and calibrated now? >> >> I was expecting to bring it back in for another rebuild this week, >> but, it is working quite well right now, and some parts I need >> wont be here until 10th November. >> >> So, I will leave it running until then. This weekend I will >> do some calibration but that will not interfere with >> reception, I will just calibrate the phase using the rising >> edge of PPS received through the antenna. >> >> -- >> Paul Nicholson >> -- >> --------------010903080704080205090008 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: 8bit The 10 char message was transmitted beginning on the 27th and 28th. On the 29th and today, the 30th, there was no transmission.
The safety function triggered again.
Yesterday as i remotely checked what happend, i saw just 70 mA instead of 300 mA. So i expected there is a fault on the coil and it was arcing.

Today i carefully inspected each of the 5 buckets and saw some small traces of partial discharges. Added loads of Kapton foil near the critical regions. Then i put the coil together again, but still 70 mA on the SpecLab antenna current plot. But the analog amperemeter near the PA showed > 320 mA! QUickly it became clear that the E field pickup probe near the antenna has dropped down during the strong storm last saturday! This also explains the sporadic interruptions during the 3 carrier experiment.

Now the probe is fixed again, the construction should be much more stable. The antenna current is recalibrated. The theoretical phase change should not be significant.
A test carrier is now running on 5170.005 Hz for an hour or so.

The 100 char message will be transmitted tomorrow 18 UTC for the 3rd time.

73, Stefan

Am 26.10.2017 19:31, schrieb DK7FC:
OK, fine. So let's start:

f = 5170.1000 Hz
Start time: 26.October.2017  18:00:00 UTC (daily)
Symbol period: 8 s
Characters: 100
CRC bits: 16
Coding 8K21A
Duration: 11:18:24h
Antenna current: 300 mA


73, Stefan



Am 26.10.2017 17:38, schrieb Paul Nicholson:

> What abbut your new E field RX, is is ready and calibrated now?

I was expecting to bring it back in for another rebuild this week,
but, it is working quite well right now, and some parts I need
wont be here until 10th November.

So, I will leave it running until then.  This weekend I will
do some calibration but that will not interfere with
reception, I will just calibrate the phase using the rising
edge of PPS received through the antenna.

--
Paul Nicholson
--

--------------010903080704080205090008--