Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on lipkowski.org X-Spam-Level: X-Spam-Status: No, score=-2.3 required=5.0 tests=FREEMAIL_FORGED_FROMDOMAIN, FREEMAIL_FROM,HEADER_FROM_DIFFERENT_DOMAINS,RCVD_IN_DNSWL_MED,SPF_PASS autolearn=ham autolearn_force=no version=3.4.0 X-Spam-DCC: dmv.com: mailn 1095; Body=2 Fuz1=2 Fuz2=2 Received: from post.thorcom.com (post.thorcom.com [195.171.43.25]) by lipkowski.org (8.14.4/8.14.4/Debian-8+deb8u1) with ESMTP id v4GEpZE6032354 for ; Tue, 16 May 2017 16:51:36 +0200 Received: from majordom by post.thorcom.com with local (Exim 4.14) id 1dAdfn-0004t4-1Q for rs_out_1@blacksheep.org; Tue, 16 May 2017 15:42:03 +0100 Received: from [195.171.43.32] (helo=relay1.thorcom.net) by post.thorcom.com with esmtp (Exim 4.14) id 1dAdfm-0004sv-6g for rsgb_lf_group@blacksheep.org; Tue, 16 May 2017 15:42:02 +0100 Received: from smtp1web.tin.it ([212.216.176.195]) by relay1.thorcom.net with esmtp (Exim 4.89) (envelope-from ) id 1dAdfj-0004FQ-CY for rsgb_lf_group@blacksheep.org; Tue, 16 May 2017 15:42:00 +0100 Received: from feu20 (10.192.64.30) by smtp1web.tin.it (8.6.060.43) id 58893FFA02332685 for rsgb_lf_group@blacksheep.org; Tue, 16 May 2017 16:41:56 +0200 Received: from (93.146.209.118) by wmlighttin.pc.tim.it; Tue, 16 May 2017 16:41:56 +0200 Message-ID: <15c11b55a0f.marcocadeddu@tin.it> Date: Tue, 16 May 2017 16:41:56 +0200 (CEST) From: "marcocadeddu@tin.it" To: Mime-Version: 1.0 X-Originating-IP: 93.146.209.118 X-Scan-Signature: 1908b49407fc556987226b536cc4bad0 Subject: R: Re: LF: RE: Combining LF amps revisited Content-Type: text/plain;charset="UTF-8" X-SA-Exim-Scanned: Yes Sender: owner-rsgb_lf_group@blacksheep.org Precedence: bulk Reply-To: rsgb_lf_group@blacksheep.org X-Listname: rsgb_lf_group X-SA-Exim-Rcpt-To: rs_out_1@blacksheep.org X-SA-Exim-Scanned: No; SAEximRunCond expanded to false X-Scanned-By: MIMEDefang 2.75 Content-Transfer-Encoding: 8bit X-MIME-Autoconverted: from quoted-printable to 8bit by lipkowski.org id v4GEpZE6032354 Status: O X-Status: X-Keywords: X-UID: 11700 Chris, I guess there is a little misstyping in the calculation performed from Clemens on the DJ5IL tool.... he entered 2.5 instead of 25 in the impedance box: the primary winding after the combiner should work on 25 ohms. If you enter 25 ohm the flux rise a lot beyond the saturation of the 3 stacked cores and therefore they have all the rights to warmup! On the other hand if you apply the Bmax formula given from Andy, the 3 stacked cores have A of 471mm² and with 2kW of power on 25 ohms the minimum number of turns on the primary should be 8 not 5. So one more turn to keep B below 0,1T and you should run more confortable with N1/N2=9/13 73 de Marco, IK1HSS ----Messaggio originale---- Da: andy.g4jnt@gmail.com Data: 15-mag-2017 14.42 A: Ogg: Re: LF: RE: Combining LF amps revisited For transformers the core is not terribly critical provided you use a grade of ferrite designed for the frequency of interest. And at LF that means SMPSU cores If I see a certain size core being used in a 500W SMPSU then there's a pretty good chance a core of the same size is going to work OK in an LF Tx of the similar rating. No data sheets or trying to work out temperature rises. I just use whatever feels right and apply the V < 4.44F.N.A.B absolutely rigorously, keeping B to less than 0.1 usually As for impedances: well they're just Z1/Z2 = SQRT(N1/N2) Use V = 4.44.F.N.A.B to give you turns min, then calculate N1 and N2 while meeting that criteria Andy G4JNT On 15 May 2017 at 11:59, Chris Wilson wrote: > Hello Clemens, > > > Thanks for the reply, the 3 stacked cores will rise to 70 degrees C > plus even with a small computer processor fan blowing through them. I > am investigating ways of reducing this, the cores are shown as 77 > material in jay's schematic, but he and I are using the newer 78 > material for the PA output transformer cores. I may try using this 76 > material in the combiner transformer. Someone else suggested making > the PA output transformers work at 100 ohms and using a > transformer less zero degree hybrid coupler. I'd try Andy's twin > primary, one secondary transformer instead of the coupler if i knew > what winding ratio and what core to start off with. Thanks again. > > > Hi Chris, > > > I have a tool by DJ5IL here which predicts around 60°C for the cores > > (excluding heat caused by the winding) > > and ca. 480 Gauss flux density. > > > 73 > > Clemens > > DL4RAJ > > > > -- > Best regards, > Chris mailto:dead_fets@gmail.com > > >