X-GM-THRID: 1203447646612424237 X-Gmail-Labels: rsgb lf X-Gmail-Received: da8fb4e1a0b9118311d0c6b7c5e9bf4561875a37 Delivered-To: daveyxm@gmail.com Received: by 10.54.72.5 with SMTP id u5cs27210wra; Mon, 15 May 2006 05:45:12 -0700 (PDT) Received: by 10.48.214.19 with SMTP id m19mr2093471nfg; Mon, 15 May 2006 05:45:11 -0700 (PDT) Return-Path: Received: from post.thorcom.com (post.thorcom.com [193.82.116.20]) by mx.gmail.com with ESMTP id k24si5703864nfc.2006.05.15.05.45.06; Mon, 15 May 2006 05:45:11 -0700 (PDT) Received-SPF: neutral (gmail.com: 193.82.116.20 is neither permitted nor denied by best guess record for domain of owner-rsgb_lf_group@blacksheep.org) Received: from majordom by post.thorcom.com with local (Exim 4.14) id 1FfcN0-0005LJ-5b for rs_out_1@blacksheep.org; Mon, 15 May 2006 13:40:18 +0100 Received: from [193.82.59.130] (helo=relay2.thorcom.net) by post.thorcom.com with esmtp (Exim 4.14) id 1FfcMz-0005LA-Nd for rsgb_lf_group@blacksheep.org; Mon, 15 May 2006 13:40:17 +0100 Received: from smtp2.versatel.nl ([62.58.50.89]) by relay2.thorcom.net with esmtp (Exim 4.51) id 1Ffdt0-0002uf-7N for rsgb_lf_group@blacksheep.org; Mon, 15 May 2006 15:17:31 +0100 Received: (qmail 13764 invoked by uid 0); 15 May 2006 12:39:59 -0000 Received: from unknown (HELO ibm) ([62.59.190.46]) (envelope-sender ) by smtp2.versatel.nl (qmail-ldap-1.03) with SMTP for < >; 15 May 2006 12:39:59 -0000 Message-ID: <000701c6781b$637b1a60$2102000a@ibm> From: "Dick" To: Date: Mon, 15 May 2006 14:29:47 +0200 MIME-Version: 1.0 X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 5.00.2615.200 X-MimeOLE: Produced By Microsoft MimeOLE V5.00.2615.200 X-Spam-Score: -0.4 (/) X-Spam-Report: autolearn=disabled,AWL=-0.915,FROM_ENDS_IN_NUMS=0.516 Subject: LF: meter problem (2) Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: 7bit X-Spam-Checker-Version: SpamAssassin 2.63 (2004-01-11) on post.thorcom.com X-Spam-Level: X-Spam-Status: No, hits=0.9 required=5.0 tests=FROM_ENDS_IN_NUMS autolearn=no version=2.63 X-SA-Exim-Scanned: Yes Sender: owner-rsgb_lf_group@blacksheep.org Precedence: bulk Reply-To: rsgb_lf_group@blacksheep.org X-Listname: rsgb_lf_group X-SA-Exim-Rcpt-To: rs_out_1@blacksheep.org X-SA-Exim-Scanned: No; SAEximRunCond expanded to false Status: O X-Status: X-Keywords: X-UID: 5526 Hello, Some more info: I measured the voltage available for the meter circuit at low and high power level. With 60W DC input I have around 3 V and with 400W DC input this goes up to around 9 - 10V My meter is 10mA full scalle. With 53mV I have full scale reading , so internal resistance around 5 Ohm. So, with around 26.5mV I have 5mA reading. So my meter should read around 0.5mA at 60W DC input (=3V from detector) and about 3.5mA at 400W DC input (9V) These are rough figures. So, I'm looking for a circuit that can do the right "transformation" so to say. Maybe it should something with an op amp. I do have plenty of TLC271 (is offset programmable TL071) in my junkbox, or use something else. Hopefully someone comes along with a schematic. Finally it doesn't have to be a circuit with very precise measuring, but a rough indication +/- 50W would be nice. Dick, PA4VHF